R_2ACTLU -------- Date: March 15, 1999 Memorandum To: All Comm-Pro ITI NCP/NEO Leased Resources (DIAL=NO) Users at the SHIP25 Distribution Level. Subject: R_2ACTLUNTFY (Optional) Problem Description: Enhancements were made to our ACTLU Response logic that reduces an unnecessary PIU exchange encountered during VTAM resource activation. In changing our ACTLU response Control Vector from Power-On (connected) to Power-Off (not connected) for the initial resource state, we eliminate some unnecessary PIU exchanges during resource ACTLU processing for X.25 resources with no current device connection. The previous default value of Power-On was causing the initial host greeting to be rejected (deferred) until the remote resource connected. Now a Notify Power-On will be delivered to the host only after the X.25 user connects. The Power-On will signal the host that the device is now able to accept output. Solution: Perform the following macro update then rerun your Comm-Pro SYSGEN. Additional APAR installation instructions can be found in the SHIP25 documentation manual in APPENDIX F (Maintenance). Please review the update header comments to identify whether UPDATE_A or UPDATE_B should be applied to your environment. ....+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8 * * UPDATE_A - TCD_GREATER_THAN_01-05-1998 * * APPLY THE FOLLOWING UPDATE IF THE TCD (TAPE CREATION DATE) OF YOUR * COMM-PRO PRODUCT DISTRIBUTION IS EARLIER THAN 01-05-1998. SEE XFM37XX * MACRO MEMBER 'IDENT' TO CONFIRM YOUR TCD. * ./ CHANGE NAME=XFLUCP,LIST=ALL ./ NUMBER SEQ1=08580023,NEW1=08580226,INCR=200,INSERT=YES 2ACTLUXF26 08580023 IC LO1,LUBCTYP PICKUP CONNECT TYPE. 2ACTLUXF26 CRI LO1,LUBCTDSP TEST FOR DSP CONNECTION. 2ACTLUXF26 BE ACTLU55 GO IF YES. 2ACTLUXF26 XRI LO1,LUBCTITI TEST FOR ITI CONNECTION. 2ACTLUXF26 BCL ACTLU60 GO IF NOT. 2ACTLUXF26 SPACE 1 2ACTLUXF26 L R1,PUBLKBPT LOCATE LKB. 2ACTLUXF26 IC HI1,LKBOPT-XFLKBD(R1) PICKUP LINK OPTIONS.25_2ACTLUXF26 BB HI1(LKBOPSWB),ACTLU60 GO IF SWITCHED LINK. 2ACTLUXF26 SPACE 1 2ACTLUXF26 ACTLU55 LRI HI1,X'01' SETUP POWER OFF NOTIFICATION. 2ACTLUXF26 B ACTLU65 GO SET CONTROL VECTOR. 2ACTLUXF26 SPACE 1 2ACTLUXF26 ACTLU60 LRI HI1,X'03' SETUP POWER ON NOTIFICATION. 2ACTLUXF26 ACTLU65 STC HI1,7(R7) INSTALL IN CONTROL VECTOR. 2ACTLUXF26 SPACE 1 2ACTLUXF26 // * * UPDATE_B - TCD_GREATER_THAN_01-05-1998_LESS_THAN_03-15-1999 * * APPLY THE FOLLOWING UPDATE IF THE TCD (TAPE CREATION DATE) OF YOUR * COMM-PRO PRODUCT DISTRIBUTION IS IN THE RANGE OF 01-05-1998 THRU * 03-14-1999. SEE XFM37XX MACRO MEMBER 'IDENT' TO CONFIRM YOUR TCD. * ./ CHANGE NAME=XFLUCP,LIST=ALL ./ NUMBER SEQ1=08580023,NEW1=08580226,INCR=200,INSERT=YES 2ACTLUXF26 08580023 IC LO1,LUBCTYP PICKUP CONNECT TYPE. 2ACTLUXF26 CRI LO1,LUBCTDSP TEST FOR DSP CONNECTION. 2ACTLUXF26 BE ACTLU55 GO IF YES. 2ACTLUXF26 XRI LO1,LUBCTITI TEST FOR ITI CONNECTION. 2ACTLUXF26 BCL ACTLU60 GO IF NOT. 2ACTLUXF26 SPACE 1 2ACTLUXF26 L R1,PUBLKBPT LOCATE LKB. 2ACTLUXF26 IC HI1,LKBOPT-XFLKBD(R1) PICKUP LINK OPTIONS.25_2ACTLUXF26 BB HI1(LKBOPSWB),ACTLU60 GO IF SWITCHED LINK. 2ACTLUXF26 SPACE 1 2ACTLUXF26 ACTLU55 LRI HI1,X'01' SETUP POWER OFF NOTIFICATION. 2ACTLUXF26 B ACTLU65 GO SET CONTROL VECTOR. 2ACTLUXF26 SPACE 1 2ACTLUXF26 ACTLU60 LRI HI1,X'03' SETUP POWER ON NOTIFICATION. 2ACTLUXF26 ACTLU65 STC HI1,7(R7) INSTALL IN CONTROL VECTOR. 2ACTLUXF26 SPACE 1 2ACTLUXF26 ./ DELETE SEQ1=08580526,SEQ2=08584026 REMOVE 1ST PASS. 2ACTLUXF26 08580526 // ....+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8 *END-OF-FILE* (THIS FILE BEST VIEWED WITH A FIXED FONT SUCH AS COURIER)